<font>The bactericidal recirculator BactoSfera is designed for safe quartzing (disinfection) of indoor air from viruses, bacteria, allergens, other infectious microorganisms and harmful substances.�</font>
<font>The main advantage of the recirculator is the possibility of quartzing the room in the presence of people, animals and plants.�Absolutely safe for humans, animals and plants.�Does not require mandatory ventilation of the room.</font>
<font>Bactericidal recirculator BactoSfera ORBB 15x2</font>
<font>Recommended for rooms of categories II, III, IV, V up to 30 m�</font>
<font>I - operating rooms, maternity, sterile areas of premises, children's wards of maternity hospitals.</font>
<font>II - dressing rooms, sterilization rooms, wards and departments of immunocompromised patients, resuscitation rooms, rooms for non-sterile zones, bacteriological and virological laboratories, blood transfusion stations, pharmaceutical shops.</font>
<font>III - chambers, offices and other premises (not included in categories I and II).</font>
<font>IV - children's playrooms, school classrooms, household premises of industrial and public buildings with a large crowd of people during a long stay.</font>
<font>V - smoking rooms, public toilets and stairwells</font>
<font>Equipped with high quality ozone-free bactericidal lamps with an ultraviolet radiation peak of 257.3 nm.�The effective life of the lamps is at least 9000 hours.</font>
<font>Bacterial efficiency 99.9%.</font>
<font>FEATURES</font>
<font>1. Programmable timer</font>
<font>You can create up to 10 different programs for automatic switching on and off of the recirculator, taking into account the days of the week, hours and minutes.�It is very convenient and effective.�For example, a program that may be convenient for your office staff: automatic activation of the recirculator every day from Monday to Friday from 9:00 to 18:30 with auto shutdown at lunchtime for 1 hour + on Saturday from 10:00 to 16:00 with auto shutdown at lunchtime + on Sunday, the recirculator is resting and so on in a circle.</font>
<font>2. Lamp health indicators</font>
<font>They signal the operability of the recirculator germicidal lamps.�The bright blue glow informs about the normal operation of the lamps, the pink glow warns of the end of the effective lamp life - it is necessary to replace the lamp with a new one, and the absence of light means that the lamp is not working.�Moreover, each indicator is responsible for the operation of one lamp.</font>
<font>3. Construction</font>
<font>The peculiarity lies in the fact that both fans in the recirculator are exhaust fans, and two air intakes protected from external penetration of direct UV-C rays are located on the side edges of the device.�This design allows you to increase the air permeability rate up to two times, so that the air is disinfected faster.�Also, inside the recirculator housing, there are sealed covers on the mounting holes for retaining the thrust (air velocity).�The recirculator case can be easily disassembled for user maintenance, and the dust filters on the exhaust fans can be obtained without disassembling the case at all - by removing the outer fan covers.</font>
�
<table cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td valign="top">
<strong><font>SPECIFICATIONS</font></strong>
</td>
<td valign="top">
<strong><font>ORBB 15X2</font></strong>
</td>
</tr>
<tr>
<td valign="top">
<font>Recommended area of the room, no more</font>
</td>
<td valign="top">
<font>30 m�</font>
</td>
</tr>
<tr>
<td valign="top">
<font>Categories of premises</font>
</td>
<td valign="top">
<font>�II, III, IV, V</font>
</td>
</tr>
<tr>
<td valign="top">
<font>UV-C radiation source</font>
</td>
<td valign="top">
<font>ozone-free germicidal lamp</font>
</td>
</tr>
<tr>
<td valign="top">
<font>Number of germicidal lamps</font>
</td>
<td valign="top">
<font>2 pcs.�15 W</font>
</td>
</tr>
<tr>
<td valign="top">
<font>Effective lamp life, not less</font>
</td>
<td valign="top">
<font>9000 hours.</font>
</td>
</tr>
<tr>
<td valign="top">
<font>Dominant wavelength</font>
</td>
<td valign="top">
<font>253.7 nm</font>
</td>
</tr>
<tr>
<td valign="top">
<font>UV-C radiation power</font>
</td>
<td valign="top">
<font>9.8 W</font>
</td>
</tr>
<tr>
<td valign="top">
<font>Air flow capacity</font>
</td>
<td valign="top">
<font>190 m� / h</font>
</td>
</tr>
<tr>
<td valign="top">
<font>Programmable timer</font>
</td>
<td valign="top">
<font>there is</font>
</td>
</tr>
<tr>
<td valign="top">
<font>Lamp health indicators</font>
</td>
<td valign="top">
<font>2 pcs.</font>
</td>
</tr>
<tr>
<td valign="top">
<font>Dust filters</font>
</td>
<td valign="top">
<font>4 pieces: 2 at the inlet + 2 at the air outlet</font>
</td>
</tr>
<tr>
<td valign="top">
<font>Electrical connection</font>
</td>
<td valign="top">
<font>3m wire with plug</font>
</td>
</tr>
<tr>
<td valign="top">
<font>Operation option</font>
</td>
<td valign="top">
<font>stationary (wall-ceiling)</font>
</td>
</tr>
<tr>
<td valign="top">
<font>Recirculator power</font>
</td>
<td valign="top">
<font>15 W</font>
</td>
</tr>
<tr>
<td valign="top">
<font>Power consumption, no more</font>
</td>
<td valign="top">
<font>35 W</font>
</td>
</tr>
<tr>
<td valign="top">
<font>Power Options</font>
</td>
<td valign="top">
<font>220 V / 50 Hz</font>
</td>
</tr>
<tr>
<td valign="top">
<font>Body material</font>
</td>
<td valign="top">
<font>metal</font>
</td>
</tr>
<tr>
<td valign="top">
<font>Weight, no more</font>
</td>
<td valign="top">
<font>3.2 kg</font>
</td>
</tr>
<tr>
<td valign="top">
<font>dimensions</font>
</td>
<td valign="top">
<font>125E125E570 mm</font>
</td>
</tr>
</tbody>
</table>