100W LNE LED Driver 12V/24V/36V/48V 100-240Vac (TYTPE2) Expand

100W LNELED Driver 12V/24V/36V/48V IP67

DELTAPSU DELTAPSU

New

by ORDER, ask for delivery time

70,60 €

Nominal Output Voltage12V24V36V
Output Voltage Adjustment Range---
Nominal Output Current8A4A2.65A
Output Power96W96W95W
Line Regulation± 0.5% (@ 90-264Vac input)± 0.5% (@ 90-264Vac input)± 0.5% (@ 90-264Vac input)
Load Regulation± 2.0% (@ 90-264Vac input, 0-100% load)± 1.0% (@ 90-264Vac input, 0-100% load)± 0.5% (@ 90-264Vac input, 0-100% load)
PARD< 150mVpp< 150mVpp< 200mVpp
Start-up Time1200ms typ. @ 115Vac (100% load)
500ms typ. @ 230Vac & 277Vac (100% load)
1200ms typ. @ 115Vac (100% load)
500ms typ. @ 230Vac & 277Vac (100% load)
1200ms typ. @ 115Vac (100% load)
500ms typ. @ 230Vac & 277Vac (100% load)
Holdup Time16ms typ. @ 115Vac & 230Vac & 277Vac (100% load)16ms typ. @ 115Vac & 230Vac & 277Vac (100% load)16ms typ. @ 115Vac & 230Vac & 277Vac (100% load)
Dynamic Response± 5% @ 0-100% load (Slew Rate: 0.1A/µS)± 5% @ 0-90% load , @ 115Vac & 230Vac & 277Vac (Slew Rate: 0.1A/µS)± 5% @ 0-100% load (Slew Rate: 0.1A/µS)± 5% @ 0-90% load , @ 115Vac & 230Vac & 277Vac (Slew Rate: 0.1A/µS)± 5% @ 0-100% load (Slew Rate: 0.1A/µS)± 5% @ 0-90% load , @ 115Vac & 230Vac & 277Vac (Slew Rate: 0.1A/µS)
Parallel ConnectionNoNoNo
Series ConnectionNoNoNo
Nominal Input Voltage100-240Vac100-240Vac100-240Vac
Input Voltage Range90-264Vac90-264Vac90-264Vac
Nominal Input Frequency50-60Hz50-60Hz50-60Hz
Input Frequency Range47-63Hz47-63Hz47-63Hz
Input Current1.30A max. @ 115Vac,
0.65A max. @ 230Vac,
0.60A max. @ 277Vac
1.30A max. @ 115Vac,
0.65A max. @ 230Vac,
0.60A max. @ 277Vac
1.30A max. @ 115Vac,
0.65A max. @ 230Vac,
0.60A max. @ 277Vac
Efficiency at 100%90.0% typ. @ 115Vac, 
92.0% typ. @ 230Vac & 27
92.0% typ. @ 115Vac,
93.0% typ. @ 230Vac & 277
91.5% typ. @ 115Vac, 
93.0% typ. @ 230Vac,<br< td="">
Max. Inrush Current65A typ. @ 230Vac65A typ. @ 230Vac65A typ. @ 230Vac
Power Factor0.98 typ. @ 115Vac,
0.95 typ. @ 230Vac,
0.93 typ. @ 277Vac
0.98 typ. @ 115Vac,
0.95 typ. @ 230Vac,
0.93 typ. @ 277Vac
0.98 typ. @ 115Vac,
0.95 typ. @ 230Vac,
0.93 typ. @ 277Vac
Leakage Current< 0.75mA @ 264Vac< 0.75mA @ 264Vac< 0.75mA @ 264Vac
Case Chassis / Case CoverAluminiumAluminiumAluminium
Dimension220 x 68 x 38.8 mm
8.66" x 2.68" x 1.53"
220 x 68 x 38.8 mm
8.66" x 2.68" x 1.53"
220 x 68 x 38.8 mm
8.66" x 2.68" x 1.53"
Unit Weight0.98 kg0.98 kg0.98 kg
Cooling SystemConvectionConvectionConvection
Noise Sound Pressure Level (SPL)Sound Pressure Level (SPL) < 25dbASound Pressure Level (SPL) < 25dbASound Pressure Level (SPL) < 25dbA
Operating Ambient Temperature-40°C to +70°C-40°C to +70°C-40°C to +70°C
Storage Ambient Temperature-40°C to +85°C-40°C to +85°C-40°C to +85°C
Power De-rating> 60°C de-rate power by 4% / °C 
< 100Vac de-rate power by 2% / Vac
> 60°C de-rate power by 4% / °C 
< 100Vac de-rate power by 2% / Vac
> 60°C de-rate power by 4% / °C 
< 100Vac de-rate power by 2% / Vac
Operating Humidity5 to 95% RH (Non-Condensing)5 to 95% RH (Non-Condensing)5 to 95% RH (Non-Condensing)
Shock Test (Non-Operating)IEC 60068-2-27, Half Sine Wave: 50G for a duration of 11ms, 3 shocks for each 3 directionsIEC 60068-2-27, Half Sine Wave: 50G for a duration of 11ms, 3 shocks for each 3 directionsIEC 60068-2-27, Half Sine Wave: 50G for a duration of 11ms, 3 shocks for each 3 directions
Vibration Test (Non-Operating)IEC 60068-2-6, Random: 5Hz to 500Hz (2.09G); 
20 min per axis for all X, Y, Z direction
IEC 60068-2-6, Random: 5Hz to 500Hz (2.09G); 
20 min per axis for all X, Y, Z direction
IEC 60068-2-6, Random: 5Hz to 500Hz (2.09G); 
20 min per axis for all X, Y, Z direction
Overvoltage Protection13.8-16.8V, Latch Mode27.6-33.6V, Latch Mode41.4-50.4V, Latch Mode
Overload/Overcurrent Protection95-108% of rated load current, constant current limit
Auto-Recovery when the fault is removed
95-108% of rated load current, constant current limit
Auto-Recovery when the fault is removed
95-108% of rated load current, constant current limit
Auto-Recovery when the fault is removed
Over Temperature ProtectionHiccup Mode, Auto-Recovery when the fault is removedHiccup Mode, Auto-Recovery when the fault is removedHiccup Mode, Auto-Recovery when the fault is removed
Short Circuit ProtectionConstant current limit, Auto-Recovery when the fault is removedConstant current limit, Auto-Recovery when the fault is removedConstant current limit, Auto-Recovery when the fault is removed
Degree of ProtectionIP67IP67IP67
Protection Against ShockClass I with Primary Earth connectionClass I with Primary Earth connectionClass I with Primary Earth connection
MTBF> 700,000 hrs. as per Telcordia SR-332
I/P: 115Vac, O/P: 100% load, Ta: 25°C
> 700,000 hrs. as per Telcordia SR-332
I/P: 115Vac, O/P: 100% load, Ta: 25°C
> 700,000 hrs. as per Telcordia SR-332
I/P: 115Vac, O/P: 100% load, Ta: 25°C
Electrical safetyCB scheme to IEC 61347-1, IEC 61347-2-13
ENEC to EN 61347-1, EN 61347-2-13, EN 62384
CCC to GB19510.1, GB19510.14
KC to KC61347-1, KC61347-2-13, KC62384
PSE to J61347-1, J61347-2-13
CB scheme to IEC 61347-1, IEC 61347-2-13
ENEC to EN 61347-1, EN 61347-2-13, EN 62384
CCC to GB19510.1, GB19510.14
KC to KC61347-1, KC61347-2-13, KC62384
PSE to J61347-1, J61347-2-13
CB scheme to IEC 61347-1, IEC 61347-2-13
ENEC to EN 61347-1, EN 61347-2-13, EN 62384
CCC to GB19510.1, GB19510.14
KC to KC61347-1, KC61347-2-13, KC62384
PSE to J61347-1, J61347-2-13
CEIn conformance with EMC Directive 2004/108/EC and Low Voltage Directive 2006/95/ECIn conformance with EMC Directive 2004/108/EC and Low Voltage Directive 2006/95/ECIn conformance with EMC Directive 2004/108/EC and Low Voltage Directive 2006/95/EC
Galvanic IsolationInput to Output: 3.85kVac
Input to Ground: 2.0kVac
Output to Ground: 1.5kVac
Input to Output: 3.85kVac
Input to Ground: 2.0kVac
Output to Ground: 1.5kVac
Input to Output: 3.85kVac
Input to Ground: 2.0kVac
Output to Ground: 1.5kVac
EmissionCISPR 15, EN 55015, GB17743
Compliance to CISPR 22, EN 55022, FCC Title 47: Class B
CISPR 15, EN 55015, GB17743
Compliance to CISPR 22, EN 55022, FCC Title 47: Class B
CISPR 15, EN 55015, GB17743
Compliance to CISPR 22, EN 55022, FCC Title 47: Class B
ImmunityEN 61547, Compliance to EN 55024EN 61547, Compliance to EN 55024EN 61547, Compliance to EN 55024
Harmonic Current EmissionsIEC/EN 61000-3-2, Class C; GB17625.1
(THD conditions: 115Vac & 230Vac @ ≥ 60% load,
277Vac @ ≥ 75% load)
IEC/EN 61000-3-2, Class C; GB17625.1
(THD conditions: 115Vac & 230Vac @ ≥ 60% load,
277Vac @ ≥ 75% load)
IEC/EN 61000-3-2, Class C; GB17625.1
(THD conditions: 115Vac & 230Vac @ ≥ 60% load,
277Vac @ ≥ 75% load)
Voltage Fluctuation and FlickerIEC/EN 61000-3-3IEC/EN 61000-3-3IEC/EN 61000-3-3
Nominal Output Voltage48V
Output Voltage Adjustment Range-
Nominal Output Current2A
Output Power96W
Line Regulation± 0.5% (@ 90-264Vac input)
Load Regulation± 0.5% (@ 90-264Vac input, 0-100% load)
PARD< 200mVpp
Start-up Time1200ms typ. @ 115Vac (100% load)
500ms typ. @ 230Vac & 277Vac (100% load)
Holdup Time16ms typ. @ 115Vac & 230Vac & 277Vac (100% load)
Dynamic Response± 5% @ 0-100% load (Slew Rate: 0.1A/µS)± 5% @ 0-90% load , @ 115Vac & 230Vac & 277Vac (Slew Rate: 0.1A/µS)
Parallel ConnectionNo
Series ConnectionNo
Nominal Input Voltage100-240Vac
Input Voltage Range90-264Vac
Nominal Input Frequency50-60Hz
Input Frequency Range47-63Hz
Input Current1.30A max. @ 115Vac,
0.65A max. @ 230Vac,
0.60A max. @ 277Vac
Efficiency at 100%92.0% typ. @ 115Vac, 
93.0% typ. @ 230Vac & 27
Max. Inrush Current65A typ. @ 230Vac
Power Factor0.98 typ. @ 115Vac,
0.95 typ. @ 230Vac,
0.93 typ. @ 277Vac
Leakage Current< 0.75mA @ 264Vac
Case Chassis / Case CoverAluminium
Dimension220 x 68 x 38.8 mm
8.66" x 2.68" x 1.53"
Unit Weight0.98 kg
Cooling SystemConvection
Noise Sound Pressure Level (SPL)Sound Pressure Level (SPL) < 25dbA
Operating Ambient Temperature-40°C to +70°C
Storage Ambient Temperature-40°C to +85°C
Power De-rating> 60°C de-rate power by 4% / °C 
< 100Vac de-rate power by 2% / Vac
Operating Humidity5 to 95% RH (Non-Condensing)
Shock Test (Non-Operating)IEC 60068-2-27, Half Sine Wave: 50G for a duration of 11ms, 3 shocks for each 3 directions
Vibration Test (Non-Operating)IEC 60068-2-6, Random: 5Hz to 500Hz (2.09G); 
20 min per axis for all X, Y, Z direction
Overvoltage Protection55.2-67.2V, Latch Mode
Overload/Overcurrent Protection95-108% of rated load current, constant current limit
Auto-Recovery when the fault is removed
Over Temperature ProtectionHiccup Mode, Auto-Recovery when the fault is removed
Short Circuit ProtectionConstant current limit, Auto-Recovery when the fault is removed
Degree of ProtectionIP67
Protection Against ShockClass I with Primary Earth connection
MTBF> 700,000 hrs. as per Telcordia SR-332
I/P: 115Vac, O/P: 100% load, Ta: 25°C
Electrical safetyCB scheme to IEC 61347-1, IEC 61347-2-13
ENEC to EN 61347-1, EN 61347-2-13, EN 62384
CCC to GB19510.1, GB19510.14
KC to KC61347-1, KC61347-2-13, KC62384
PSE to J61347-1, J61347-2-13
CEIn conformance with EMC Directive 2004/108/EC and Low Voltage Directive 2006/95/EC
Galvanic IsolationInput to Output: 3.85kVac
Input to Ground: 2.0kVac
Output to Ground: 1.5kVac
EmissionCISPR 15, EN 55015, GB17743
Compliance to CISPR 22, EN 55022, FCC Title 47: Class B
ImmunityEN 61547, Compliance to EN 55024
Harmonic Current EmissionsIEC/EN 61000-3-2, Class C; GB17625.1
(THD conditions: 115Vac & 230Vac @ ≥ 60% load,
277Vac @ ≥ 75% load)
Voltage Fluctuation and FlickerIEC/EN 61000-3-3
Output100W
CATEGORYPower supply adapter

Delta Electronics Group is a multi-billion dollar global company and the world’s leading producer of power supplies for the top names in industrial, medical and consumer electronics devices. For more than 40 years, Delta has been a well regarded and tr