30W Sync series 24V Expand

30W Sync series 24V

DELTAPSU DELTAPSU

New

by ORDER, ask for delivery time

18,82 €

Nominal Output Voltage24V
Output Voltage Adjustment Range21.6-26.4Vdc
Nominal Output Current1.25A
Output Power30W
Line Regulation< 1% typ. (@ 85-264Vac, 100% load)
Load Regulation< 1% typ. (@ 85-264Vac, 100% load)
PARD150mVpp
Start-up Time< 3,000ms @ 115Vac 
< 1,600ms @ 230Vac (100% load)
Holdup Time> 20ms @ 230Vac (100% load)
Dynamic Response± 5% @ 10-100% load
Start-up with Capacitive Loads3,000μF Max
Parallel ConnectionNo
Series ConnectionNo
Nominal Input Voltage100-240Vac
Input Voltage Range85-264Vac
Nominal Input Frequency50-60Hz
Input Frequency Range47-63Hz
Input Current< 0.80A@115Vac, < 0.40A @ 230Vac
Efficiency at 100%88.0% typ.@ 230Vac
Max. Inrush Current< 60A @ 230Vac
Leakage Current< 0.5mA @ 240Vac
Case Chassis / Case CoverPlastic
Dimension75 x 21 x 89.5 mm
2.95" x 0.83" x 3.52"
Unit Weight0.10 kg
Cooling SystemConvection
Input Terminal3 Pins (Rated 300V/16A)
Output Terminal2 Pins (Rated 300V/16A)
WireAWG 26-12
Operating Ambient Temperature-20°C to +70°C
Storage Ambient Temperature-40°C to +85°C
Power De-rating-10°C to -20°C de-rate power by 5% / °C
> 55°C de-rate power by 3.33% / °C
Operating Humidity5 to 95% RH (Non-Condensing)
Overvoltage Protection< 34.8V, SELV Output, Auto-Recovery
Overload/Overcurrent Protection110-150% of rated load current, Hiccup Mode, 
Non-Latching (Auto-Recovery when the fault is removed)
Over Temperature ProtectionAuto-Recovery
Short Circuit ProtectionAuto-Recovery when the fault is removed
Degree of ProtectionIP20
Protection Against ShockClass I with PE connection
MTBF> 700,000 hrs. as per Telcordia SR-332
I/P: 100Vac, O/P: 100% load, Ta: 35°C
Electrical safetyUL/cUL listed to UL 508 and 
CSA C22.2 No. 107.1-01 (File No. E338991),
GB9254, GB17625.1 and GB4943.1
ITETUV Bauart to EN 60950-1, 
UL/cUL recognized to UL 60950-1, CSA C22.2 No. 60950-1 (File No. E131881), 
CB scheme to IEC 60950-1, 
Limited Power Source (LPS)
CEIn conformance with EMC Directive 2004/108/EC and 
Low Voltage Directive 2006/95/EC
Galvanic IsolationInput to Output: 3.0 KVac
Input to Ground: 1.5 KVac
Output to Ground: 0.5 KVac
EmissionCISPR 22, EN 55022, EN 61000-6-3, EN 61000-6-4, 
FCC Title 47: Class B
ImmunityEN 55024
Voltage Fluctuation and FlickerIEC/EN 61000-3-3
CATEGORYPower supply adapter

Delta Electronics Group is a multi-billion dollar global company and the world’s leading producer of power supplies for the top names in industrial, medical and consumer electronics devices. For more than 40 years, Delta has been a well regarded and tr