No products
Prices are tax included
Nominal Output Voltage | 12V | 24V | |
Nominal Output Current | 0.83A | 0.42A | |
Output Power | 10W | 10W | |
Line Regulation | < 1% typ. (@ 90-264Vac, 100% load) | < 1% typ. (@ 90-264Vac, 100% load) | |
Load Regulation | < 2% typ. (@ 90-264Vac, 100% load) | < 2% typ. (@ 90-264Vac, 100% load) | |
PARD | < 50mVpp | ||
Start-up Time | < 3,000ms @ nominal input (100% load) | < 3,000ms @ nominal input (100% load) | |
Holdup Time | > 10ms @ 115Vac, > 30ms @ 230Vac (100% load) | > 10ms @ 115Vac, > 30ms @ 230Vac (100% load) | |
Dynamic Response | ± 5% @ 10-100% load (Overshoot & Undershoot O/P Voltage) | ± 5% @ 10-100% load | |
Start-up with Capacitive Loads | 3,000µF Max | ||
Parallel Connection | No | No | |
Series Connection | No | No |
Nominal Input Voltage | 100-240Vac | 100-240Vac | |
Input Voltage Range | 90-264Vac 125-375Vdc | 90-264Vac | |
Nominal Input Frequency | 50-60Hz | 50-60Hz | |
Input Frequency Range | 47-63Hz | 47-63Hz | |
Nominal DC Input Voltage | 125-375Vdc | 125-375Vdc | |
Input Current | < 0.30A@115Vac, < 0.20A @ 230Vac | < 0.30A @ 115Vac, < 0.20A @ 230Vac | |
Efficiency at 100% | > 82.0% @ 115Vac & 230Vac | > 80.0% @ 115Vac & 230Vac | |
Max. Inrush Current | < 15A @ 115Vac, < 30A @ 230Vac | < 15A @ 115Vac, < 30A @ 230Vac | |
Leakage Current | < 0.25mA @ 240Vac | < 0.25mA @ 240Vac |
Case Chassis / Case Cover | Plastic | Plastic | |
Dimension | 91 x 18 x 55.6 mm 3.58" x 0.71" x 2.19" | 91 x 18 x 55.6 mm 3.58" x 0.71" x 2.19" | |
Unit Weight | 0.06 kg | 0.065 kg | |
Cooling System | Convection | ||
Input Terminal | M4 x 2 Pins (Rated 300V/16A) | M4 x 2 Pins (Rated 300V/16A) | |
Output Terminal | M4 x 2 Pins (Rated 300V/16A) | M4 x 2 Pins (Rated 300V/16A) | |
Mounting Rail | Standard TS35 DIN Rail in accordance with EN 60715 |
Operating Ambient Temperature | -25°C to +71°C | -25°C to +71°C | |
Storage Ambient Temperature | -25°C to +85°C | -25°C to +85°C | |
Power De-rating | > 55°C de-rate power by 2.5% / °C | > 55°C de-rate power by 2.5% /°C | |
Operating Humidity | 5 to 95% RH (Non-Condensing) | 5 to 95% RH (Non-Condensing) | |
Shock Test (Non-Operating) | IEC 60068-2-27, Half Sine Wave: 4G for a duration of 22ms, 3 shocks for each 3 directions, 9 times in total | IEC 60068-2-27, Half Sine Wave: 4G for a duration of 22ms, 3 shocks for each 3 directions, 9 times in total | |
Vibration Test (Non-Operating) | IEC 60068-2-6, Sine Wave: 10-500Hz @ 19.6m/SІ (2G peak); 10 min per cycle, 60 min for all X, Y, Z directions | IEC 60068-2-6, Sine Wave: 10-500Hz @ 19.6m/SІ (2G peak); 10 min per cycle, 60 min for all X, Y, Z directions |
Overvoltage Protection | < 17.4V, SELV Output, Latch-off Mode | < 34.8V, SELV Output, Latch-off Mode | |
Overload/Overcurrent Protection | > 105% of rated load current, Hiccup Mode, Non-Latching (Auto-Recovery when the fault is removed) | > 120% of rated load current, Hiccup Mode, Non-Latching (Auto-Recovery when the fault is removed) | |
Over Temperature Protection | > 75°C Surrounding Air Temperature @ 100% load, Latch-off Mode | > 75°C Surrounding Air Temperature @ 100% load, Latch-off Mode | |
Short Circuit Protection | Hiccup Mode, Non-Latching (Auto-Recovery when the fault is removed) | Hicc-up Mode, Non-Latching (Auto-Recovery when the fault is removed) | |
Degree of Protection | IP20 | IP20 | |
Protection Against Shock | Class II (No Primary Earth connection is required) |
MTBF | > 500,000 hrs. as per Telcordia SR-332 I/P: 100Vac, O/P: 100% load, Ta: 35°C | > 500,000 hrs. as per Telcordia SR-332 |
Electrical safety | UL/cUL listed to UL 508 and CSA C22.2 No. 107.1-01 (File no. E338991) | UL/cUL listed to UL 508 and CSA C22.2 No. 107.1-01 (File no. E338991) | |
ITE | TUV Bauart to EN 60950-1, UL/cUL recognized to UL 60950-1 and CSA C22.2 No. 60950-1 (File no. E131881), CB scheme to IEC 60950-1, Limited Power Source (LPS) | TUV Bauart to EN 60950-1, UL/cUL recognized to UL 60950-1 and CSA C22.2 No. 60950-1 (File no. E131881), CB scheme to IEC 60950-1, Limited Power Source (LPS) | |
CE | In conformance with EMC Directive 2004/108/EC and Low Voltage Directive 2006/95/EC | In conformance with EMC Directive 2004/108/EC and Low Voltage Directive 2006/95/EC | |
Galvanic Isolation | Input to Output: 3.0KVac |
Emission | CISPR22, EN55022, FCC Title 47: Class B | ||
Immunity | EN55024 |
CATEGORY | Power supply adapter |
Delta Electronics Group is a multi-billion dollar global company and the world’s leading producer of power supplies for the top names in industrial, medical and consumer electronics devices. For more than 40 years, Delta has been a well regarded and tr