60W/100W CliQ series 12V/24V Expand

60W/100W CliQ series 12V/24V

DELTAPSU DELTAPSU

New

by ORDER, ask for delivery time

31,68 €

Nominal Output Voltage12V24V12V
Output Voltage Adjustment Range11-14Vdc22-28Vdc11-14Vdc
Nominal Output Current5A2.5A8.33A
Output Power60W60W100W
Line Regulation< 0.5% typ. (@ 85-264Vac input, 100% input)< 0.5% typ. (@ 85-264Vac input, 100% load)< 0.5% typ. (@85 to 264 Vac Input 100% load)
Load Regulation< 1% typ. (@ 85-264Vac input, 0-100% input)< 1% typ. (@ 85-264Vac input, 0-100% load)< 1% typ. (@85 to 264 Vac Input 0-100% load)
Start-up Time< 2500ms @ nominal input (100% load, 25°C)< 3000ms @ nominal input (100% load, 25°C)< 600ms @ nominal input (100% load, 25°C)
Holdup Time> 22ms @ 115Vac,
> 110ms @ 230Vac (100% load, 25°C)
> 20ms @ 115Vac,
> 125ms @ 230Vac (100% load, 25°C)
> 22ms @ 115Vac,
> 110ms @ 230Vac (100% load, 25°C)
Dynamic Response± 5% @ 10-100% load± 5% @ 10-100% load± 5% @ 10-100% load
Start-up with Capacitive Loads8,000µF Max8,000µF Max10,000µF Max
Parallel ConnectionNoNoNo
Series ConnectionNoNoNo
Residual Ripple/PARD(20MHz)< 100mVpp @ 25°C
Nominal Input Voltage100-240Vac100-240Vac100-240Vac
Input Voltage Range85-264Vac 120-375 Vdc85-264Vac 120-375 Vdc85-264Vac 120-375 Vdc
Nominal Input Frequency50-60Hz50-60Hz50-60Hz
Input Frequency Range47-63Hz47-63Hz47-63Hz
Nominal DC Input Voltage125-250Vdc
Input Current< 1.35A @ 115Vac,
< 0.80A @ 230Vac
< 1.10A @ 115Vac,
< 0.70A @ 230Vac
< 2.50A @ 115Vac,
< 1.50A @ 230Vac
Efficiency at 100%> 86.0% @ 115Vac & 230Vac> 86.0% @ 115Vac,
> 87.0% @ 230Vac
> 85.5% @ 115Vac,
> 87.5% @ 230Vac
Max. Inrush Current< 50A @ 115Vac,
< 100A @ 230Vac
< 40A @ 115Vac,
< 80A @ 230Vac
< 100A @ 115Vac,
No Damage @ 230Vac
Power FactorConform to EN61000-3-2Conform to EN61000-3-2Conform to EN61000-3-2
Leakage Current< 1mA @ 240Vac< 1mA @ 240Vac< 1mA @ 240Vac
Case Chassis / Case CoverAluminiumAluminiumAluminium
Dimension121 x 32 x 120 mm
4.76" x 1.26" x 4.72"
121 x 32 x 120 mm
4.76" x 1.26" x 4.72"
121 x 50 x 118.7 mm
4.76" x 1.97" x 4.67"
Unit Weight0.33 kg0.37 kg0.64 kg
Cooling SystemConvectionConvectionConvection
Input TerminalM4 x 3 Pins (Rated 300V/20A)M4 x 3 Pins (Rated 300V/20A)M4 x 3 Pins (Rated 300V/20A)
Output TerminalM4 x 2 Pins (Rated 300V/20A)M4 x 2 Pins (Rated 300V/20A)M4 x 2 Pins (Rated 300V/20A)
Operating Ambient Temperature-20°C to +75°C-20°C to +75°C-20°C to +75°C
Storage Ambient Temperature-25°C to +85°C-25°C to +85°C-25°C to +85°C
Power De-rating> 50°C de-rate power by 2.5% /°C,
> 70°C de-rate by 4% /°C
Vertical: < 0°C de-rate power by 1% / °C, > 50°C de-rate power by 2.5% /°C
Horizontal: < 0°C de-rate power by 1% / °C, > 50°C de-rate power by 2.5% / °C,
> 70°C de-rate power by 4% / °C
> 50°C de-rate power by 2.5% /°C ,
> 70°C de-rate power by 4% /°C
Operating Humidity5 to 95% RH (Non-Condensing)< 95% RH (Non-Condensing)5 to 95% RH (Non-Condensing)
Shock Test (Non-Operating)IEC60068-2-27, 30G (300m/SІ) for a duration of 18msIEC60068-2-27, 30G (300m/SІ) for a duration of 18msIEC60068-2-27, 30G (300m/SІ) for a duration of 18ms
Vibration Test (Non-Operating)IEC60068-2-6, 10Hz to 150Hz @ 50m/SІ (5G peak); 90 min per axis for all X, Y, Z directionIEC60068-2-6, 10Hz to 150Hz @ 50m/SІ (5G peak); 90 min per axis for all X, Y, Z directionIEC60068-2-6, 10Hz to 150Hz @ 50m/SІ (5G peak); 90 min per axis for all X, Y, Z direction
Overvoltage Protection16V +10% / -5%, SELV Output, Hicc-up Mode, Non-Latching (Auto-Recovery)32V +10%, SELV Output, Hicc-up Mode, Non-Latching (Auto-Recovery)16V +10% / -5%, SELV Output, Hicc-up Mode, Non-Latching (Auto-Recovery)
Overload/Overcurrent Protection> 150% of rated load current, Hicc-up Mode, Non-Latching (Auto-Recovery)> 150% of rated load current, Hicc-up Mode, Non-Latching (Auto-Recovery)> 150% of rated load current, Hicc-up Mode, Non-Latching (Auto-Recovery)
Over Temperature Protection< 80°C Surrounding Air Temperature @ 100% load, Non-Latching (Auto-Recovery)< 80°C Surrounding Air Temperature @ 100% load, Non-Latching (Auto-Recovery)< 80°C Surrounding Air Temperature @ 100% load, Non-Latching (Auto-Recovery)
Short Circuit ProtectionHicc-up Mode, Non-Latching (Auto-Recovery when the fault is removed)Hicc-up Mode, Non-Latching (Auto-Recovery when the fault is removed)Hicc-up Mode, Non-Latching (Auto-Recovery when the fault is removed
Degree of ProtectionIPX0IPX0IPX0
Protection Against ShockClass I without Primary Earth connectionClass I without Primary Earth connectionClass I without Primary Earth connection
MTBF> 800,000 hrs. as per Telcordia SR-332> 800,000 hrs. as per Telcordia SR-332> 800,000 hrs. as per Telcordia SR-332
Electrical safetyUL/cUL listed to UL 508 and CSA C22.2 No. 107.1-01 (File No. E315355),
CSA to CSA C22.2 No. 107.1-01 (File No. 181564)
UL/cUL listed to UL 508 and CSA C22.2
No. 107.1-01 (under alternate part number EOE11010006 of File no. E315355),
CSA to CSA C22.2 No. 107.1-01 (under alternate part number EOE11010006
of File No. 181564)
UL/cUL listed to UL 508 and CSA C22.2 No. 107.1-01 (File No. E315355),
CSA to CSA C22.2 No. 107.1-01 (File No. 181564)
ITETUV to EN 60950-1, 
UL/cUL recognized to UL 60950-1 and CSA C22.2 No. 60950-1 (File No. E191395), 
CB scheme to IEC 60950-1
SIQ to EN 60950-1, UL/cUL recognized to UL 60950-1 and CSA C22.2 
No. 60950-1 (under alternate part number EOE11010006 of File no. E191395),
CSA to CSA C22.2 No. 60950-1 and UL 60950-1,
CB scheme to IEC 60950-1
TUV to EN 60950-1, 
UL/cUL recognized to UL 60950-1 and CSA C22.2 No. 60950-1 (File No. E191395), 
CB scheme to IEC 60950-1
CEInconformance with EMC directive 2004/108/EC and low voltage directive 2006/95/ECIn conformance with EMC Directive 2004/108/EC and Low Voltage Directive 2006/95/ECInconformance with EMC directive 2004/108/EC and low voltage directive 2006/95/EC
Galvanic IsolationInput to Output: 4.0KVac,
Input to Ground: 1.5KVac,
Output to Ground: 1.5KVac
Input to Output: 4.0KVac
Input to Ground: 1.5Kvac
Output to Ground: 1.5KVac
Input to Output: 4.0KVac,
Input to Ground: 1.5KVac,
Output to Ground: 1.5KVac
EmissionCISPR22, EN55022, EN55011, FCC Title 47: Class BCISPR22, EN55022, EN55011, FCC Title 47: Class BCISPR22, EN55022, EN55011, FCC Title 47: Class B
ImmunityEN55024: 1998/A1:2001/ A2:2003 Level 3; EN61000-4-2, Level 4 “Criteria A”EN55024: 1998/A1:2001/ A2:2003 Level 3; EN61000-4-2, Level 4 “Criteria A”EN55024: 1998/A1:2001/ A2:2003 Level 3; EN61000-4-2, Level 4 “Criteria A”
Output100W
CATEGORYPower supply adapter

Delta Electronics Group is a multi-billion dollar global company and the world’s leading producer of power supplies for the top names in industrial, medical and consumer electronics devices. For more than 40 years, Delta has been a well regarded and tr