100W PMT series 12/5V_24/5V Expand

100W PMT series 12/5V_24/5V

DELTAPSU DELTAPSU

New

  • Conforms to harmonic current IEC/EN 61000-3-2, Class A
  • Selectable AC Switch (88-132Vac176-264Vac)
  • High MTBF > 700,000 hrs. as per Telcordia SR-332
  • Versatile configuration options (Enclosed, L Frame)
  • Versatile connector options (Terminal Block, Front Face, Harness)

More details

by ORDER, ask for delivery time

30,72 €

Nominal Output Voltage12/5V24/5V
Output Voltage Adjustment RangeV1: 10.8-13.2VdcV1: 21.6-26.4Vdc
Nominal Output Current7A / 3A3.5A / 3A
Output Power99W99W
Line Regulation± 0.5% typ. (@ 100-132Vac & 200-264Vac)± 0.5% typ. (@ 100-132Vac & 200-264Vac)
Load RegulationV1: ± 1% typ. (@ 100-132Vac & 200-264Vac )
V2: ± 2% typ. (@ 100-132Vac & 200-264Vac )
V1: ± 1% typ. (@ 100-132Vac & 200-264Vac )
V2: ± 2% typ. (@ 100-132Vac & 200-264Vac )
PARDV1: < 120mVpp,
V2: < 80mVpp
V1: < 120mVpp,
V2: < 80mVpp
Start-up Time< 1200ms @ 115Vac,
< 2000ms @ 230Vac (100% load)
< 1200ms @ 115Vac,
< 2000ms @ 230Vac (100% load)
Holdup Time> 20ms @ 115Vac,
> 25ms @ 230Vac
> 20ms @ 115Vac,
> 25ms @ 230Vac
Dynamic Response± 5% @ 0-100% load± 5% @ 0-100% load
Start-up with Capacitive Loads8,000μF Max8,000μF Max
Parallel ConnectionNoNo
Series ConnectionNoNo
Nominal Input Voltage100-120Vac, 200-240Vac (Selectable by Switch)100-120Vac, 200-240Vac (Selectable by Switch)
Input Voltage Range88-132Vac Selectable by Switch 176-264Vac88-132Vac Selectable by switch 176-264Vac
Nominal Input Frequency50-60Hz50-60Hz
Input Frequency Range47-63Hz47-63Hz
Input Current2.00A@115Vac,
< 1.20A @ 230Vac
< 2.00A@115Vac,
< 1.20A @ 230Vac
Efficiency at 100%> 82.0% typ. @ 230Vac> 84.0% typ. @ 230Vac
Max. Inrush Current< 45A typ. @ 230Vac< 45A typ. @ 230Vac
Leakage Current< 0.25mA @ 240Vac< 0.25mA @ 240Vac
Case Chassis / Case CoverAluminium / SGCCAluminium / SGCC
Dimension178 x 97 x 38 mm
7.01" x 3.82" x 1.50"
178 x 97 x 38 mm
7.01" x 3.82" x 1.50"
Unit Weight0.45 kg0.42 kg
IndicatorGreenLED (DC OK)
Cooling SystemConvectionConvection
Input TerminalPM☐-D1V100W1AA☐: M3.5 x 7 Pins (Rated 300V/15A)
PM☐-D1V100W1AG☐: M3.5 x 7 Pins (Rated 300V/20A)
PM☐-D1V100W1AH☐: (JWT): A3963WV2-5P-A
PM☐-D2V100W1AA☐: M3.5 x 7 Pins (Rated 300V/15A)
PM☐-D2V100W1AG☐: M3.5 x 7 Pins (Rated 300V/20A)
PM☐-D2V100W1AH☐: (JWT): A3963WV2-5P-A
Output TerminalPM☐-D1V100W1AA☐: M3.5 x 7 Pins (Rated 300V/15A)
PM☐-D1V100W1AG☐: M3.5 x 7 Pins (Rated 300V/20A)
PM☐-D1V100W1AH☐: (JWT): A3963WV2-7P-U
PM☐-D2V100W1AA☐: M3.5 x 7 Pins (Rated 300V/15A)
PM☐-D2V100W1AG☐: M3.5 x 7 Pins (Rated 300V/20A)
PM☐-D2V100W1AH☐: (JWT): A3963WV2-7P-U
Operating Ambient Temperature-10°C to +70°C-10°C to +70°C
Storage Ambient Temperature-25°C to +85°C-25°C to +85°C
Power De-rating> 50°C de-rate power by 2.5% / °C
< 100Vac de-rate power by 0.8% / 1V
> 50°C de-rate power by 2.5% / °C
< 100Vac de-rate power by 0.8% / 1V
Operating Humidity5 to 95% RH (Non-Condensing)5 to 95% RH (Non-Condensing)
Shock Test (Non-Operating)IEC 60068-2-27, Half Sine: 50G for a duration of 11ms, 3 times per direction, 18 times in totalIEC 60068-2-27, Half Sine: 50G for a duration of 11ms, 3 times per direction, 18 times in total
Vibration Test (Non-Operating)IEC 60068-2-6, Random: 5Hz to 500Hz (2.09Grms); 20 min per axis for all X, Y, Z directionIEC 60068-2-6, Random: 5Hz to 500Hz (2.09Grms); 20 min per axis for all X, Y, Z direction
Overvoltage ProtectionV1: 115-135%, Hicc-up Mode, Non-Latching (Auto-Recovery)V1: 115-135%, Hicc-up Mode, Non-Latching (Auto-Recovery)
Overload/Overcurrent ProtectionV1: 110-150%, Hicc-up Mode, Non-Latching (Auto-Recovery)V1: 110-150%, Hicc-up Mode, Non-Latching (Auto-Recovery)
Over Temperature ProtectionHicc-up Mode, Non-Latching (Auto-Recovery when the fault is removed)Hicc-up Mode, Non-Latching (Auto-Recovery when the fault is removed)
Short Circuit ProtectionHicc-up Mode, Non-Latching (Auto-Recovery when the fault is removed)Hicc-up Mode, Non-Latching (Auto-Recovery when the fault is removed)
Reverse Polarity ProtectionClass I with Primary Earth connection
Protection Against ShockClass I with Primary Earth connection
MTBF> 700,000 hrs. as per Telcordia SR-332> 700,000 hrs. as per Telcordia SR-332
ITETUV Bauart to EN 60950-1,
UL/cUL recognized to UL 60950-1 and CSA C22.2 No. 60950-1 (File no. E131881),
CB scheme to IEC 60950-1, CCC to GB4943
TUV Bauart to EN 60950-1,
UL/cUL recognized to UL 60950-1 and CSA C22.2 No. 60950-1 (File no. E131881), 
CB scheme to IEC 60950-1, CCC to GB4943
CEIn conformance with EMC Directive 2004/108/EC and Low Voltage Directive 2006/95/ECIn conformance with EMC Directive 2004/108/EC and Low Voltage Directive 2006/95/EC
Safety ApprovalsTUV Bauart to EN 60950-1, UL/cUL recognized to UL 60950-1 and CSA C22.2 No. 60950-1, CB scheme to IEC 60950-1, CCC to GB4943TUV Bauart to EN 60950-1, UL/cUL recognized to UL 60950-1 and CSA C22.2 No. 60950-1, CB scheme to IEC 60950-1, CCC to GB4943
Galvanic IsolationInput to Output: 3.0 KVac
Input to Ground: 1.5 KVac
Output to Ground: 0.5 KVac
Input to Output: 3.0 KVac
Input to Ground: 1.5 KVac
Output to Ground: 0.5 KVac
EmissionCISPR 22, EN 55022, FCC Title 47: Class BCISPR 22, EN 55022, FCC Title 47: Class B
Harmonic Current EmissionsIEC/EN 61000-3-2, Class AIEC/EN 61000-3-2, Class A
Voltage Fluctuation and FlickerIEC/EN 61000-3-3IEC/EN 61000-3-3
Output100W
CATEGORYPower supply adapter

Delta Electronics Group is a multi-billion dollar global company and the world’s leading producer of power supplies for the top names in industrial, medical and consumer electronics devices. For more than 40 years, Delta has been a well regarded and tr